SilverStone Strider Plus ST60F-PS Power Supply Review

Manufacturer: SilverStone

Efficiency, Differential Temperature and Noise

Efficiency

Efficiency is defined by the power output divided by the power input and is usually expressed as a percentage.  If a PSU were a 100% efficient (which none are) 600 watts of AC power going in would result in 600 watts of DC power coming out (with no waste heat to dissipate).  In the real world there are always inefficiencies and power is lost in the form of heat during the conversion process. Newer revisions to the ATX12V Power Supply Design Guide V 2.2 have continued to increase the efficiency recommendations for PC switching mode power supplies and now lists both required and recommended minimum efficiencies.

View Full Size

We measured the AC power input to the Strider Plus ST60F-PS PSU with an Extech power analyzer while the total DC load was found by adding all the individual +3.3V, +5V, +12V, -12V and +5VSB loads together. 

View Full Size

View Full Size

The overall efficiency of the Strider Plus ST60F-PS power supply is very good and meets the criteria for 80Plus Silver certification, even while operating on 115 VAC and at elevated temperatures.  When operating on 240 VAC, the efficiency numbers were easily compliant with the 80Plus Gold criteria, just as SilverStone claims.

80 Plus Program

View Full Size

Note 1: Power Factor ≥0.90 (50% to 100% Load)
Note 2: Tests conducted at room temperature (25°C)

Differential Temperature and Noise Levels

To simulate real world operation, some of the warm exhaust air from the PSU under test is recirculated back to the intake through a passive air duct, which allows the PSU air inlet temperature to increase with load, just like it would in a real PC. 

The differential temperature across the power supply was calculated by subtracting the internal case air temperature (T in) from the temperature of the warm exhaust air flowing out the back of the power supply (T out). 

Thermocouples were placed at the air inlet and exhaust outlet. The ambient room air temperature was 23ºC (74ºF) +/- 0.5ºC during testing.

T out = temperature of air exhausting from power supply
T in = temperature of air entering power supply
Delta T = T out - T in

Sound pressure level readings were taken 3’ away from the rear of the case in an otherwise quiet room.  The ambient noise level was ~27 dBA. 

View Full Size

The ST60F-PS power supply fan speed starts out relatively slow and is very quiet through ~50% load with relatively cool ambient temperatures. At full load with the simulated case air temperature increasing, the fan really ramped up and became very noticeable.

Note: I was not able to take SPL measurements at the higher loads due to the background noise created by all the programmable DC load cooling fans running constantly. At the lower loads I am usually able to catch a moment when all the load fans have cycled off to take a SPL reading.

No comments posted yet.

Post new comment

The content of this field is kept private and will not be shown publicly.
  • Lines and paragraphs break automatically.
  • Allowed HTML tags: <a> <em> <strong> <cite> <code> <ul> <ol> <li> <dl> <dt> <dd> <blockquote><p><br>
  • Web page addresses and e-mail addresses turn into links automatically.

More information about formatting options

By submitting this form, you accept the Mollom privacy policy.